The radiosurgical RF300 adopts 1,750 MHz Frequency Technology , is in the middle band of radio frequencies and with cutting power up to 200 watts.
This frequency was chosen to minimize arising from the current during electrosurgical procedures, giving the system the following practical advantages:
- Negligible electrolytic effect due to the very short period unidirectional current conduction.
-Absence of phenomena of muscular electrostimulation, as a result of scrolling extremely superficial current..
The Radiosurgical RF300, as a modern electrosurgical, can operate with
- 2 Cut functions , 2 Coag functions, 2 Bipolar functions
It can also operate in differents modes:
- Continuous
- Timed (with a minimum pulse duration of 1/100 of a second).
- Autorepeat (Trains of pulses with variable frequency from 3 to 20 Hertz).
- Superpulsed (With the possibility to vary, depending on the condition, both duration and frequency repetition of the pulses).
In particular this function, allows to operate over skin surface with very low thermal spread and limiting surrounding tissue damage.

The Radiosurgical system is entirely controlled by a microprocessor
ALARMS :
• SAFETY PLATE NOT PROPERLY APPLIED TO THE PATIENT / CONNECTOR PATIENT PLATE NOT PROPERLY INSERTED (Only for the monopolar mode).
• HF LEAKAGE CURRENT OVER THE LIMITS .
• INTERNAL FAULT
MAIN APPLICATIONS
• Dermatology
• Gynaecology
• ORL
• Proctology
• Plastic surgery, cosmetic and reconstructive
• General Surgery
• Dentistry
• Ophthalmology
• Neurosurgery
• Laparoscopy
• Arthroscopy
TECHNICAL SPECIFICATIONS RF300 -200W-
• Supply voltage: 220-240 Vac, 50/60 Hz
• Working frequency RF: 1.750 KHz
• Operation: Temporary
• Output power (CUT1-CUT2-COAG1): 200 W eff. (+ / - 20%)
• Output power (COAG2): 130 W eff. (+ / - 20%)
• Output power (Bipo): 80 W eff. (+ / - 20%)
• Output impedance (COAG1 and bipolar): 125/175 ohms
• Output impedance (CUT1-CUT2): 375/575 ohms
• Output impedance (COAG2): 1475/1575 ohm
• Bipolar Output circuit: Floating high insulation
• Monopolar output circuit referenced to ground for HF
• Current leakage H.F.: <150 mA
• Power supply: 350 V.A. max
• Line protection: 2 fuses 2A fast
• Internal protection: 1 fuse 4A rit. - 1 Fuse 0.1 A rit.
• Activation Control : Double Foot-switch or Fingers hand piece
• Power adjustment: Continuously from 3 to 100 units
• Functions: 4 (CUT1-CUT2-COAG1-COAG2)
• Programmable power: Separate CUT and COAG
• Operating modes: 4 modes, both monopolar and bipolar
• Class of protection: I type BF - IPx1
• Safety circuit plate: Active with double locking plate
• Dimensions: 450 x 350 x 140 mm
• Weight: 11 kg