SURGERY EQUIPMENT

  AM308N

  RF300

  TRIUMPH

  ACCESSORIES

SURGERY AND AESTHETIC EQUIPMENT

  TS200

  TS200 FRACTIONAL

MEDICAL AESTHETIC EQUIPMENT

PHOTODYNAMIC THERAPY EQUIPMENT

LASER EQUIPMENT

PHOTOTHERAPY EQUIPMENT

AM308N

     

The radiosurgical AM308N adopts a technology operating at 1,750 MHz, and in the middle band of radio frequencies and with cutting power up to 100 watts.

The choice frequency  was dictated by the need to minimize the damage resulting from the use of the current in electrosurgical procedures giving the system the following practical advantages:

- Negligible electrolytic effect due to the very short period of unidirectional current conduction .
- No phenomena of electrical muscle stimulation as a result of the extremely sliding of current over the surface  .

The AM308N radiosurgical , in addition to the traditional functions, can operate in:
- Continuous.
- Timed (with a minimum pulse duration of 1 hundredth of a second).
- Autorepeat (trains of pulses with variable Frequency from 3 to 20 Hertz).
- Superpulsed , with the possibility to vary both paramentrs, depending on the
condition (duration of the pulses and Frequency repetition).


This function, in particular, allows to operate in surface
with very low thermal spread and limited damage to surrounding tissues.

 

 

The Radiosurgical system is entirely controlled by a microprocessor

 

ALARMS :

• SAFETY PLATE  NOT PROPERLY APPLIED TO THE PATIENT / CONNECTOR PATIENT PLATE NOT PROPERLY INSERTED (Only for the monopolar mode).
• HF LEAKAGE CURRENT OVER THE LIMITS .
• INTERNAL FAULT

 

MAIN APPLICATIONS

 

• Dermatology
• Gynaecology
• ORL
• Proctology
• Plastic surgery, cosmetic and reconstructive
• General Surgery
• Dentistry
• Ophthalmology
• Neurosurgery
• Laparoscopy
• Arthroscopy

 

TECHNICAL SPECIFICATIONS AM308N  -100W-

  • • Supply voltage: 220-240 Vac, 50/60 Hz
    • Working frequency RF: 1.750 KHz
    • Operation: Temporary
    • Output power (CUT1-CUT2-COAG1): 100 W eff. (+ / - 20%)
    • Output power (COAG2): 70 W eff. (+ / - 20%)
    • Output power (Bipo): 80 W eff. (+ / - 20%)
    • Output impedance (COAG1 and bipolar): 125/175 ohms
    • Output impedance (CUT1-CUT2): 375/575 ohms
    • Output impedance (COAG2): 1475/1575 ohm
    • Bipolar Output circuit: Floating high insulation
    • Monopolar output circuit  referenced to ground for HF
    • Current leakage H.F.: <150 mA
    • Power supply: 350 V.A. max
    • Line protection: 2 fuses 2A fast
    • Internal protection: 1 fuse 4A rit. - 1 Fuse 0.1 A rit.
    • Activation Control  : Double Foot-switch or Fingers hand piece
    • Power adjustment: Continuously from 3 to 100 units
    • Functions: 4 (CUT1-CUT2-COAG1-COAG2)
    • Programmable power: Separate CUT and COAG
    • Operating modes: 4 modes, both monopolar and bipolar
    • Class of protection: I type BF - IPx1
    • Safety circuit plate: Active with double locking plate
    • Dimensions: 450 x 350 x 140 mm
    • Weight: 11 kg
  •  

 

Download the brochure of the product:

 Download the User Manual:

 

 

 

ABOUT

Company

Products

HELP

Faq

Contacts

JOIN US

Facebook

Linkedin

DOWNLOADS

Download pdf

Epem s.r.l. // Via Galliano, 2 -50144 Firenze - ITALY
Tel. +39.055.331412 - Fax +39.055.331402
P.iva 04537940480 - C.C.I.A.A. Fi. N° 0462295

All copyright and other intellectual property rights
in this material are either owned by Touch or have
been licensed to it by the owner(s) of those rights
so that it can use this material as part of this website.